Delta Electronics — 14.2.6 SSI Input Counting

AS Series Module Manual Data Format – User-Defined: Users can define all parameters based on the illustration in the following diagram. Data length Parity Check Length .. Multi-turn data length Single-turn data length Status data length . ........ ........ ........ Multi-turn start bit Parity check Single-turn Status data Parity check start bit start bit start bit start bit Note: For a multi-turn encoder, the multi-turn data and single-turn data should be next to each other without additional data placed between them. Example 1: 25-bit Single-Turn Encoder MSB LSB Data Length (bits) : 25 Multi-Turn Data Length (bits): 0 Single-Turn Data Length (bits): 25 Single-Turn Data Start Bit:

b24 Status Data Length (bits): 0 Parity Check: No check Single-turn data 14-14 b1 b0 Item Setting Default Data Length (bits) 7 ~ 31 25 Multi-Turn Data Length (bits) 0 ~ 31 12 Multi-Turn Data Start Bit B0 ~ b30 B24 Single-Turn Data Length (bits) 1 ~ 31 13 Single-Turn Data Start Bit B0 ~ b30 B12 Status Data Length (bits) 0 ~ 15 0 Status Data Start Bit B0 ~ b30 B0 Parity Check No check, odd parity check, even parity check No check Parity Check Bit B0 ~ b30 B0 Parity Check Start Bit B0 ~ b30 B0 Parity Check Length (bits) 0 ~ 30 0 14 b24 b23 b22 b21 b20 b19 b18 b17 b16 b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0