Delta Electronics — 14.2.6 SSI Input Counting

Chapter 14 High Speed Counter Module AS02HC 14 9. Ring Counter Overflow / Underflow Detection The Ring Counter Overflow/Underflow Detection function is enabled on the Alarm Setting tab page of the HWCONFIG software. The alarm will appear as the counter value overflow/underflow occurs. 2 31 -1 2 31 -1 0 Counter value 0 10. SSI Encoder Rotation Rate Restriction -2 31 -2 31 For the SSI input counting, the rotation rate restriction is influenced by the SSI encoder resolution and monoflop time. Use the corresponding formula in the following table to calculate the rotation speed of the SSI encoder. See the reference values for the formula above in the following table.

14-17 Ring Counter 231-1 231-1 2Res olution 2Res olution Counter Zero Zero Zero Zero value crossing crossing crossing crossing counting 0 counting up 0 down The absolute position of SSI encoder Ring counter -231 -231 Zero rossing Zero crossing counting up Zero crossing counting down Ring counter overflow Counting up Counting up Ring counter underflow Counting down Counting down Encoder type Rotation rate (RPM) Single-turn encoder 60 ± (tp: monoflop time, unit: us) 2×tp×10−6 Multi-turn encoder 60×2MT data length ± (tp: monoflop time, unit: us) 2×tp×10−6 Max. rotation rate Max.

rotation rate Monoflop time of single-turn encoders of multi-turn encoders (us) (RPM) (RPM) 64 468750 468750 ✕ 2MT data length 4000 7500 7500 ✕ 2MT data length 8000 3750 3750 ✕ 2MT data length 12000 2500 2500 ✕ 2MT data length