AS Series Programming Manual DDRVI and DDRVA support the output devices for D 1 which can be the odd points as shown in the following table. Only the Pulse+direction output mode is supported. It is not recommended that you use the input points Y0.0, Y0.2–Y0.10 as the high-speed output points. 4. The output point for the pulse direction output device D 2 is affected by the scan cycle if it is not the recommended output point in the table above. 5. When D 2 uses the output mode Pulse+direction and S 1 has a minus sign, D 2 is ON. When S 1 has a plus sign, D 2 is OFF. D 2 is not OFF immediately after the pulse output in the negative direction is completed.
D 2 switches to OFF when the contact for the execution of the instruction is OFF. _6 6. For the instruction execution, you must use the parameters such as the start/end frequency and ramp-up/down time. Refer to the following table for SM/SR corresponding to the axes. The following table applies when D 1 selects the even output points as the output devices.
6-810 Axis number Axis 1 Axis 2 Axis 3 Axis 4 Axis 5 Axis 6 Output point for D1 Y0.0 Y0.2 Y0.4 Y0.6 Y0.8 Y0.10 Direction output point for D2 Y0.1 Y0.3 Y0.5 Y0.7 Y0.9 Y0.11 Output mode SR462 SR482 SR502 SR522 SR542 SR562 Axis number Axis 7 Axis 8 Axis 9 Axis 10 Axis 11 Axis 12 Output point for D1 Y0.1 Y0.3 Y0.5 Y0.7 Y0.9 Y0.11 Direction output point for D2 Y1.0 or above or any M device (BOOL) Output point for D1 Y0.0 Y0.2 Y0.4 Y0.6 Y0.8 Y0.10 Busy flag SM460 SM480 SM500 SM520 SM540 SM560 Completion flag SM461 SM481 SM501 SM521 SM541 SM561 Reversing the output SM462 SM482 SM502 SM522 SM542 SM562 direction Stop flag SM463 SM483 SM503 SM523 SM543 SM563 Enabling S curve SM468 SM488 SM508 SM528 SM548 SM568 ramp-up/down Enabling fixed slope SM469 SM489 SM509 SM529 SM549 SM569 ramp-up/down Output completion SM470 SM490 SM510 SM530 SM550 SM570 auto-reset