Delta Electronics — 6.26.2 Explanation of High-speed Output Instructions

AS Series Programming Manual  When the interrupt for the mark alignment does not occur or has no effect, DDRVM stops outputting the pulses after the target number of pulses specified by S 1 . S 4 : The number of output pulses in the fore mask section. If the interrupt occurs in this section, the interrupt is ineffective for the mark alignment. S 5 : The number of output pulses in the rear mask section. If the interrupt occurs in this section, the interrupt is ineffective for the mark alignment. S 2 : The target output frequency _6 2. The mark alignment function is enabled in the ramp-up and target frequency and ramp-down sections.

When the mark alignment function is not enabled, set S 1 = 100,000; the output stops after 100,000 pulses.  Green line: signal of mark aligment  Blue line: the actual output speed 6-834