AS Series Programming Manual _6 Symbol Group : Group number Module : Module number ChNo : Channel number Stable : Specify stable-weight range (0.0~100000.0) ZeroS : Clear the weight to 0 TareS :
Flag to set the tare weight 6-438 API Instruction Operand Description 1416 D LCWEI Group, Module ~ ErrCode Reading weight value via LC module Device X Y M S T C HC D FR SM SR E K 16# “$” F Group Module ChNo Stable ZeroS TareS TareW Weight Status Error ErrCode BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type Group Module ChNo Stable ZeroS TareS TareW Weight Status Error ErrCode Pulse Instruction 16-bit instruction 32-bit instruction - - AS