Delta Electronics ASD-B2 — P0-xx Monitor Parameters

Chapter 7 Parameters ASDA-B2 P0-03 Settings: MON2 MON1 Not used Please refer to parameter P1-04, P1-05 for proportional setting of analog output voltage. For example: P0-03 = 01 (MON1 is the analog output of motor speed; MON2 is the analog output of motor torque) MON1 output voltage = 8 Ч Note: (Max. speed Ч P1−04 Motor speed 100 ) (unit : Volts) MON2 output voltage = 8 Ч (Max. torque Ч P1−05 Motor torque 100 ) (unit: Volts) P0-04 ■ 7-14 Address: 0006H MON Analog Monitor Output 0007H Operation Interface: Panel/Software Communication Related Section: 6.6.3 Default: 00 Control Mode: ALL Unit: - Range: 00 ~ 77 Data Size: 16-bit Format:

Hexadecimal MON1, MON2 Setting Value Description 0 Motor speed (+/-8 Volts/Max. speed) 1 Motor torque (+/-8 Volts/Max. torque) 2 Pulse command frequency (+8 Volts/4.5Mpps) 3 Speed command (+/-8 Volts/ Max. speed command) 4 Torque command (+/-8 Volts/Max. torque command) 5 VBUS voltage (+/-8 Volts/450V) 6 Reserved 7 Reserved Address: 0008H Reserved 0009H