Delta Electronics — 3.9.2 The potential danger of STO

ASDA-B3 Wiring 3.9 STO function (Safe Torque Off) 3.9.1 Introduction to STO Once the STO function is enabled, the servo drive stops supplying current to the motor, cutting 3 off the power supply and torque force. Do not repeatedly use this function for it does not stop the motor with active force. Note: 1. The STO function is supported by the B3A series only. 2. STO certification application is in progress. 3.9.2 The potential danger of STO After the STO function is enabled, the motor is no longer controlled by the servo motor. Thus, take all the potential danger resulted from enabling the STO function into consideration.

Delta is not liable for mechanical damage and personnel injury if you fail to observe the following instructions: 1. For a safety circuit design, make sure the selected components conform to the safety specifications. 2. Before installation, read the safety instructions in the STO-related user manual for the components you use. 3. Do not touch the servo drive when the STO function is enabled. Although the power to the motor is cut off, there is residual electricity since the power supply is not completely removed from the servo drive. When maintaining the servo drive, use the molded case circuit breaker (MCCB) or magnetic contactor (MC) to cut off the power. 4.

When the STO function is enabled, the servo drive can no longer control, stop, or decelerate the motor. 5. After the STO function is enabled, the servo drive no longer controls the motor, but the motor can still be moved by other external forces. 6. The feedback monitoring output signal (FDBK) is only for inspecting the STO function status rather than for safety output. 7. The STO function must be powered by the safety extra-low voltage (SELV) power source with reinforced insulation. 8. Power the STO signals with single power supply, or the leakage current will result in STO malfunction. 3-69