Delta Electronics — 3.8 CN10 STO connector (Safe torque off)

Wiring ASDA-B3 3.8 CN10 STO connector (Safe torque off) This connector provides the STO function. More details are provided in the next section. 3 Note: 1. The STO function is supported by the B3A series only. 2. STO certification application is in progress. 8 6 7 5 4 3 2 1 (2) (1) CN10 STO connector (female); (2) CN10 quick connector (male) Pin assignment: If you do not need the STO function, plug in the STO connector that comes with the servo drive. The wiring has been done as shown in the figure on the right. If this connector has been disassembled, refer to Section 3.9 STO function (Safe Torque Off) for wiring information. 3-68 (1) Pin No.

Signal Description 1 Reserved Reserved 2 Reserved Reserved 3 STO A _ STO input A+ 4 /STO A _ STO input A- 5 STO B _ STO input B+ 6 /STO B _ STO input B- 7 FDBK+ STO alarm output (+), BJT Output Max. rating: 80 VDC, 0.5 A 8 FDBK- STO alarm output (-), BJT Output Max. rating: 80 VDC, 0.5 A