Delta Electronics — 3.7.2 Wiring for the EtherCAT communication connector

ASDA-B3 Wiring  EtherCAT error indicator (ERR) 3 Init (SI) (OI) (SP) Safe-operational (OS) Operational State switching diagram Connecting multiple servo drives: Note: 1. When multiple servo drives are connected, the maximum distance between each drive is 50 m (164.04 inches). 2. Use CAT5e STP cable. 3. It is suggested to use a Beckhoff cable (model number: ZB9020). 3-67 Indicator Status Description Off No error No error has occurred. On PDI Watchdog timeout Servo drive malfunction. Contact the distributor for assistance. Blinking State change error Parameter setting error causes the system unable to switch states. Refer to the following diagram.

Single flash Synchronization error / SyncManager error The synchronization between the controller and the servo drive failed or the data was lost during data reception. ( (IP) (PI) PLC (1)