Delta Electronics — 3.7.2 Wiring for the EtherCAT communication connector

Wiring ASDA-B3 3.7.2 Wiring for the EtherCAT communication connector Two ports are provided for connecting multiple servo drives, with one way in and the other way 3 out. 1 8 9 16 (2) (1) CN6 connector (female); (2) CN6 connector (male) Pin assignment (same for both connectors): Description of each indicator for the CN6 connector:  Network status indicator  EtherCAT connection status indicator (RUN) 3-66 (1) Pin No. Terminal Signal Description 1, 9 TX+ TX+ Transmit + 2, 10 TX- TX- Transmit - 3, 11 RX+ RX+ Receive + 4, 12 - - - 5, 13 - - - 6, 14 RX- RX- Receive - 7, 15 - - - 8, 16 - - - Indicator Status Description On Network is connected. Connection is established but no data transmission.

Blinking Connection is established and in data transmission. Data in transmission. Off No connection. Connection is not established. Indicator Status Description Off Initial After power cycling and the initialization of the servo drive is complete, the communication has not yet started, but the controller can access the servo drive’s register. On Operational SDO, TxPDO, and RxPDO data packets can be transmitted. Blinking Pre-operational The controller can exchange data through the mailbox. Single flash Safe-operational The servo drive can use the SDO and TxPDO data packets to exchange data with the controller.