Delta Electronics — 3.9.4.1 Activation status

ASDA-B3 Wiring 3.9.4 How does the STO function work? The STO function controls the motor current by two individual circuits. It cuts off the power supply to the motor when needed, after which the motor is free from torque force. When an STO 3 alarm occurs, determine the alarm type according to the pin status of the feedback monitor signal (FDBK). The following table details how this function works. Description of action and feedback status: Note: 1. ON = 24V; OFF = 0V. 2. Open = open circuit; Close = short circuit. 3. The status of the feedback monitor signal switches immediately based on the safety signal source changes. 4. Contact the distributor if AL503 occurs.

Refer to Chapter 12 Troubleshooting for more details. 3.9.4.1 Activation status STO reaction time: When one of the safety signal source is low, the circuit cuts off the motor current within 20 ms. STO_A / STO_B Motor current 3-71 Signal Safety Status of opto-isolator signal source STO STO A _ ~ / STO A _ ON ON OFF OFF STO B _ ~ / STO B _ ON OFF ON OFF Servo drive output status Ready Torque off (STO B lost) _ Torque off (STO A lost) _ Torque off (STO mode) Feedback monitor signal (FDBK status) Open Close Open Open Alarm N/A AL500 AL501 AL502 H L Max. 20 ms OFF ON