Delta Electronics — 4.5.1 Testing without load

ASDA-B3 Test Operation and Panel Display 4.5 Testing This section is divided into two parts. The first part introduces testing without load and the second part describes testing when running the servo motor with load. To avoid danger, operate 4 the servo motor without load first. 4.5.1 Testing without load Remove the load from the servo motor, including coupling on the shaft and accessories, to avoid any damage to the servo drive or machine. This prevents the disassembled parts of the motor shaft from falling off and possibly causing personnel injury or equipment damage during operation. Run the motor without load first to see if the servo motor can run during normal operation. Caution:

to prevent danger, it is strongly recommended that you check if the motor can operate normally without load first. Then, try operating the motor with load. Check the following items carefully before operation. 4-13 Inspection before operation (without power)  Check for any obvious visible damage.  The wires at the wiring terminal should be isolated.  Make sure the wiring is correct to avoid damage or any abnormal operation.  Check for and remove any electrically conductive objects, including metal (such as screws) or inflammable objects inside or near the servo drive.  Check that the control switch is in the Off state.

 Do not place the servo drive or external regenerative resistor on inflammable objects.  Make sure the circuits for the emergency stop and circuit breaker function normally. These functions need to be activated once the electromagnetic brake malfunctions..  Reduce the electromagnetic interference if there is electronic interference with the peripheral devices.  Make sure the external voltage level of the servo drive is correct. Inspection during operation (power is applied)  Protect the encoder cable from excessive stress. When the motor is running, make sure the cable is not worn or stretched.  Contact Delta if the servo motor vibrates or makes unusual noise during operation.

 Make sure the settings for the parameters are correct. Different machinery has different characteristics. Adjust the parameters according to the characteristics of each machine.  Reset the parameters when the servo drive is in the Servo Off state, or it may cause malfunction.  If there is no contact noise or other abnormal noise when the relay is operating, please contact Delta.  Check if the power indicator and LED display work properly.