Test Operation and Panel Display ASDA-B3 4.4.3 Digital input diagnosis operation You can switch to the Diagnosis mode by the following steps. When DI1 - DI9 are triggered by 4 the external signal, the panel shows the corresponding signal in bit. When it shows 1, it means the DI is on. For example, if it shows 1FE1, E is in hexadecimal format; it will be 1110 when it transfers to binary format. Then, DI6 - DI8 are on. The panel displays in hexadecimal format. 13 12 11 10 9 8 7 6 5 4 3 2 1 Corresponding DI status Binary code (Display in hexadecimal format) 4.4.4 Digital output diagnosis operation You can switch to the Diagnosis mode by the following steps.
When DO1 - DO6 are triggered by the output signal, the panel shows the corresponding signal in bit. When it shows 1, it means the DO is on. For example, if it shows 1F, F is in hexadecimal format; it will be 1111 when it transfers to binary format. Then, DO1 - DO4 are on. SET The panel displays in hexadecimal format Binary code 5 4 3 2 1 Corresponding DO status (Display in hexadecimal format) 4-12 S S ET 1 1 1 1 1 1 1 1 0 0 0 0 1 0 0 0 1 1 1 1 1