Delta Electronics — 4.5.2 Apply power to B3 servo drive

ASDA-B3 Test Operation and Panel Display  When the screen displays: 4 Positive limit error warning: Check if any of the digital inputs DI1 - DI9 are set to positive limit (PL) and make sure that DI is off. Corrective action: 1. If you do not want to set the positive limit (PL) as one of the digital inputs, make sure none of the digital inputs DI1 - DI9 are set to positive limit (PL) (make sure that none of 2. If the positive limit (PL) function is needed, make sure this DI is on when it is preset as the parameters, P2.010 - P2.017 and P2.036, are set to 23). normally closed (function code: 0x0023), and then set this DI as normally open (function code: 0x0123).  When the screen displays:

Overcurrent warning: Corrective action: 1. Check the connection between the motor and servo drive. 2. Check if the conducting wire is short-circuited. Fix the short circuit and prevent any metal conductors from being exposed.  When the screen displays: Undervoltage warning: Corrective action: 1. Check if the main circuit wiring is correct. 2. Use a voltmeter to check the main circuit voltage. 3. Use a voltmeter to measure if the power system complies with the specifications. Note: during power on or in the Servo On state (without issuing any commands), if an alarm occurs or any abnormal display appears, contact the distributor. 4-17