Delta Electronics — 4.5.3 JOG trial run without load

Test Operation and Panel Display ASDA-B3 4.5.3 JOG trial run without load It is easy to test the motor and servo drive using a JOG trial run without load since no extra wiring 4 is needed. For safety reasons, it is recommended to set JOG at low speed. Follow these steps: Step 1: JOG trial run is available only when the servo drive is in the Servo On state. The drive can be forced into the Servo On state by setting P2.030 to 1 or with the host controller. (JOG trial run with panel operation is not available in the Communication mode.) Step 2: set JOG speed (unit: rpm) with P4.005. Press the SET key to display the JOG speed. The default is 20 rpm. Step 3:

press the ▲ or ▼ key to adjust the JOG speed. In the following example, the speed is set to 100 rpm. Step 4: press the SET key to display JOG and enter JOG mode. Step 5: press the MODE key after completing the trial run to exit JOG mode. SET Display JOG speed. Its default value is 20 rpm. Press the keys to adjust the JOG speed. Adjust the speed to 100 rpm. SET Display JOG and enter JOG mode. JOG mode After entering JOG mode, press the or key to make the motor run in counterclockwise or clockwise direction. Release the key to stop the operation. P (CCW) N (CW) MODE Press the MODE key to exit JOG mode. Exit 4-18