ASDA-B3 Tuning 5.1.2 Differences between gain adjustment modes 5 Note: 1. For more information on the parameter functions, refer to Section 5.3 Gain adjustment modes. 2. When the two-degrees-of-freedom control function is disabled (set P2.094 [Bit 12] to 0), the effect of Gain adjustment mode 3 is the same as that of Gain adjustment mode 2, so setting P2.089 is invalid in that scenario.
5-3 P2.032 Adjustment mode Inertia estimation Parameter setting Manual Auto value 0 Manual Fixed set value of P1.037 P1.037, P2.000, P2.004, P2.006, P2.023, P2.024, P2.025, P2.043, P2.044, P2.045, P2.046, P2.049, P2.089, P2.098, P2.099, P2.101, P2.102 N/A 1 Gain adjustment mode 1 Real-time estimation P2.031 P1.037, P2.000, P2.004, P2.006, P2.023, P2.024, P2.025, P2.043, P2.044, P2.045, P2.046, P2.049, P2.089, P2.098, P2.099, P2.101, P2.102 2 Gain adjustment mode 2 Fixed set value of P1.037 P1.037, P2.031 P2.000, P2.004, P2.006, P2.023, P2.024, P2.025, P2.043, P2.044, P2.045, P2.046, P2.049, P2.089, P2.098, P2.099, P2.101, P2.102 3 Gain adjustment mode 3 (only when the two-degrees-of- freedom control function is enabled) Fixed set value of P1.037 P1.037, P2.031, P2.089 P2.000, P2.004, P2.006, P2.023, P2.024, P2.025, P2.043, P2.044, P2.045, P2.046, P2.049, P2.098, P2.099, P2.101, P2.102 4 Gain adjustment mode 4 Reset to gain default value - -