Delta Electronics — 6.2.4 S-curve filter for Position commands

ASDA-B3 Operation Mode The upper path of the above diagram is the PR mode and the lower one is the PT mode that you can select with P1.001. You can set the E-Gear ratio in both modes to adjust the positioning resolution. In addition, you can use either a moving filter or low-pass filter to smooth the 6 command (described as follows). The Pulse Command Input Inhibit (INHP) function In PT mode, when DI.INHP is on, the servo drive stops receiving external pulse commands and the motor stops running. As this function is only supported by DI4, setting P2.017 (DI4) to 0x45 (DI.INHP) is required.

DI.INHP ON ON OFF Pulse command 6.2.4 S-curve filter for Position commands The S-curve filter for Position commands smoothes the motion command in PR mode. The filter makes the speed and acceleration continuous and reduces jerking, resulting in a smoother mechanical operation. If the load inertia increases, the motor operation is influenced by friction and inertia when the motor starts or stops rotating. Setting a larger acceleration / deceleration constant for the S-curve (P1.036) and the acceleration / deceleration time in P5.020 - P5.035 can increase the smoothness of operation.

When the Position command source is pulse, the speed and angular acceleration are continuous, so the S-curve command filter is not necessary. Position Speed Time (ms) Rated speed Time (ms) Torque Time (ms) AC0 - 15 2 2 P1.036 2 P1.036 2 Position and S-curve speed and time setting (incremental position command) 6-7 AC0 - 15 P1.036 P1.036