Delta Electronics — 6.2.8 Gain adjustment of the position loop

ASDA-B3 Operation Mode 6.2.8 Gain adjustment of the position loop There are two types of gain adjustment for the position loop: auto and manual.  Auto 6 The ASDA-B3 servo drive provides an Auto Tuning function that allows you to easily complete the gain adjustment. Refer to Chapter 5 Tuning for a detailed description.  Manual Before setting the position control unit, you have to manually set the speed control unit (P2.004 and P2.006) since a speed loop is included in the position loop. Then set the position control gain (P2.000) and position feed forward gain (P2.002). Description of the position control gain and position feed forward gain: 1. Position control gain:

the higher the gain, the larger bandwidth for the position loop response. 2. Position feed forward gain: reduces the deviation of phase delay. Note that the position loop bandwidth should not be larger than the speed loop bandwidth. Calculation: 4 fv fp  (fv: response bandwidth of speed loop (Hz); fp: response bandwidth of position loop (Hz).) KPP = 2 Ч  Ч fp Example: if the desired position bandwidth is 20 Hz, then adjust KPP (P2.000) to 125. (2 Ч  Ч 20 Hz = 125) Refer to Chapter 8 for detailed descriptions of the relevant parameters.

Position control unit Position command 6-11 Parameter Function P2.000 Position control gain P2.002 Position feed forward gain Position feed Position feed forward gain Differentiator forward gain smoothing constant P2.002 P2.003 Position + + control gain + P2.000 - Position control gain rate of change Gain switching P2.001 P2.027 Position counter Maximum speed limit P1.055 Speed command Encoder