ASDA-B3 Operation Mode 6.3 Speed mode There are two kinds of command sources: analog input and internal register (parameters). The analog command controls the motor speed by scaled external voltage input. The command 6 register input controls the speed in two ways. Before operation, respectively set the speed values in three registers. You can switch among the three sets of speed either by using DI.SPD0 / DI.SPD1 of CN1 or change the value in the register through communication. In order to deal with the problem of non-continuous speed when switching registers, you can use the S-curve acceleration and deceleration filter.
6.3.1 Selecting the Speed command source There are two types of Speed command sources: analog voltage and internal register (parameters). Select the command source with DI signals of CN1. See the following table for more details. Status of SPD0 and SPD1: 0 means that DI is off (the circuit is open); 1 means that DI is on (the circuit is closed). When both SPD0 and SPD1 are 0, if it is in Sz mode, the command is 0. Thus, if the Speed command using analog voltage is not required, you can use Sz mode to address the problem of zero drift in the voltage. If it is in S mode, the command is the voltage difference between V_REF and GND.
The range of the input voltage is between -10V and +10V, and you can adjust the corresponding speed (P1.040). When either one of SPD0 and SPD1 is not 0, the Speed command comes from the internal register. The command is activated once the status of SPD0 and SPD1 are switched. There is no need to use DI.CTRG for triggering. The parameter setting range (internal register) is -60000 to 60000. Rotation speed = setting value x unit (0.1 rpm). For example, if P1.009 = +30000, then rotation speed = +30000 x 0.1 rpm = +3000 rpm Use the Speed command in Speed mode (S or Sz) and in Torque mode (T or Tz) to set the speed limit.
6-15 Speed CN1 DI signal command Command source Content Range number SPD1 SPD0 S1 0 0 Mode S External analog signal Voltage difference between V REF and _ GND -10V to +10V Sz N/A Speed command is 0 0 S2 0 1 Register parameter P1.009 -60000 to 60000 S3 1 0 P1.010 -60000 to 60000 S4 1 1 P1.011 -60000 to 60000