Delta Electronics — 6.3.2 Control structure of Speed mode

Operation Mode ASDA-B3 6.3.2 Control structure of Speed mode The basic control structure is shown in the following flowchart. 6 Speed command The Speed command processing unit selects the command source (see Section 6.3.1), including the scaling parameter (P1.040) for maximum rotation speed corresponding to the analog voltage and the S-curve parameter for smoothing the speed. The Speed control unit manages the gain parameters for the servo drive and calculates the current command for servo motor in real-time. The Resonance suppression unit suppresses the resonance of the machine. The following diagram introduces the function of Speed command processing unit.

Its structure is shown as follows. SPD0 and SPD1 signals of CN1 Register P1.009 - S-curve filter P1.036 P1.011 Command Low-pass filter S-curve filter for selection P1.001 P1.006 A/D Scaling P1.040 analog commands P1.059 The upper path is the command from the register and the lower one is the command from the Analog signal external analog voltage that you can select with the status of SPD0 and SPD1, and P1.001 (S or Sz). In this condition, the S-curve and low-pass filters are applied to achieve a smoother response. 6-16 Speed command processing unit Speed estimator Speed control Resonance Current Torque limit Motor unit suppression unit loop Speed control unit Motor