Delta Electronics — 6.3.4 Scaling of the analog command

ASDA-B3 Operation Mode 6.3.4 Scaling of the analog command In the analog mode, control the motor’s Speed command by the analog voltage difference between V_REF and GND. Use P1.040 and P1.081 (maximum rotation speed for analog Speed 6 command) to adjust the slope of the speed change and its range. P1.082 can change the filter switching time between P1.040 and P1.081. Speed command P1.081 = 6000 P1.040 = 3000 input (V) Analog voltage Refer to Chapter 8 for detailed descriptions of the relevant parameters.

6-19 6000 rpm 3000 rpm 0 -5 P P 5 10 3000 rpm 6000 rpm Parameter Function P1.040 First set of maximum rotation speed for analog Speed command P1.081 Second set of maximum rotation speed for analog Speed command P1.082 Filter switching time between P1.040 and P1.081