ASDA-B3 Operation Mode 6.3.6 Gain adjustment of the speed loop The structure of the speed control unit is shown in the following diagram. Speed control unit 6 In the speed control unit, you can adjust different types of gain. You can adjust the gain manually or use the two gain adjustment modes provided. Manual: manually set the parameters, and all auto or auxiliary functions are disabled. Gain adjustment mode: refer to Chapter 5 Tuning. Manual mode When you set P2.032 to 0, you also set the speed control gain (P2.004), speed integral compensation (P2.006), and speed feed forward gain (P2.007). The parameter descriptions are as follows. Speed control gain:
the higher the gain, the larger the bandwidth for the speed loop response. Speed integral compensation: increasing this gain increases the low frequency rigidity and reduces the steady-state error. However, this sacrifices the phase margin. If you set this gain too high, it reduces the system stability. Speed feed forward gain: reduces the deviation of phase delay. Refer to Chapter 8 for detailed descriptions of the relevant parameters.
6-21 Speed feed Differentiator forward gain P2.007 System inertia J (1+P1.037)*JM Speed control + + + + gain + P2.004 - + + Integrator Gain Load inertia Rate of switching ratio change P2.027 P1.037 Speed integral P2.005 compensation P2.006 Motor inertia Gain switching JM P2.027 Torque constant Torque Current reciprocal command command 1/KT Low-pass filter Speed P2.049 estimator Encoder Parameter Function P2.004 Speed control gain (KVP) P2.006 Speed integral compensation (KVI) P2.007 Speed feed forward gain (KVF)