ASDA-B3 Operation Mode 6.4.2 Control structure of Torque mode The following diagram shows the basic control structure of Torque mode. Output torque 6 Torque command Torque command processing unit Resonance suppression unit Motor + Current control unit - Current sensor The Torque command processing unit selects the command source (see Section 6.4.1), including the scaling parameter (P1.041) for rotation speed and S-curve parameter for smoothing the torque. The current control unit manages the gain parameters for the servo drive and calculates the current for servo motor in real-time; you can only set this by commands. The structure of torque command processing unit is as follows.
TCM0 and TCM1 signals of CN1 Register P1.012 - P1.014 Command Low-pass filter selection P1.001 P1.007 A/D Scaling P1.041 Analog signal The upper path is the command from the register and the lower one is the command from the external analog voltage that you can select with the status of TCM0 and TCM1, and P1.001 (T or Tz). Adjust the torque with the analog voltage scaling (P1.041) and smooth the response with the low-pass filter (P1.007). 6-27