Delta Electronics — 7.1.1 Shared PR parameters

ASDA-B3 Motion Control ASDA-Soft also provides a user-friendly interface for this shared PR parameter function (see Figure 7.1.1.2). In these data, the acceleration or deceleration time is set based on the length of time for motor to accelerate from 0 to 3000 rpm or to decelerate from 3000 rpm to 0. For instance, if the acceleration time is set to 50 ms, when the target speed for the motion 7 command is 3000 rpm, then the required duration is 50 ms. If the target speed for the motion command is 1500 rpm, then the acceleration time is 25 ms. The acceleration or deceleration time is a fixed slope, so the slope does not change when you change parameter values.

PR path setting ACC:1 DEC:4 DLY:2 SPD:5 Acceleration / deceleration time 0 1 2 3 4 5 6 ... 14 15 (ACC / DEC) Delay time (DLY) Target speed (SPD) 0 1 2 3 4 5 6 ... 14 15 0 1 2 3 4 5 6 ... 14 15 Figure 7.1.1.1 Shared parameter data for PR paths Figure 7.1.1.2 ASDA-Soft interface for shared PR parameter data 7-5 P5.020 200 P5.021 300 P5.022 500 P5.023 600 P5.024 800 P5.025 900 P5.026 1000 ... P5.034 50 P5.035 30 P5.040 0 P5.041 100 P5.042 200 P5.043 400 P5.044 500 P5.045 800 P5.046 1000 ... P5.054 5000 P5.055 5500 P5.060 20.0 P5.061 50.0 P5.062 100.0 P5.063 200.0 P5.064 300.0 P5.065 500.0 P5.066 600.0 ... P5.074 2500.0 P5.075 3000.0