Delta Electronics — 7.1.2 Monitoring variables of PR mode

Motion Control ASDA-B3 7.1.2 Monitoring variables of PR mode The PR mode provides four monitoring variables for the servo commands and feedback status: command position (PUU), PR command end register, feedback position (PUU), and position 7 error (PUU). These are described as follows: 1. Command position (PUU): monitoring variable code 001, simplified as Cmd_O (Command Operation). The target position of the motion command generated per scan cycle during servo operation (updated every 1 ms). 2. PR command end register: monitoring variable code 064, simplified as Cmd_E (Command End). The target position of the PR command.

When a command is triggered, the servo drive calculates the target position and then updates to PR command end register. 3. Feedback position (PUU): monitoring variable code 000, simplified as Fb_PUU (Feedback PUU). The feedback position (coordinates) for the motor. 4. Position error (PUU): monitoring variable code 002, simplified as Err_PUU (Error PUU). The deviation between the command position (PUU) and the feedback position (PUU). How these four monitoring variables work is shown in Figure 7.1.2.1. After the servo issues a Position command, the servo sets the position of Cmd_E once the target position data is acquired.

The motor operates to the target position based on the PR path setting. Cmd_O calculates the amount of command deviation in each fixed cycle and sends it to the servo drive, where it is treated as a dynamic command. Fb_PUU is motor encoder feedback position and Err_PUU is the deviation of Cmd_O minus Fb_PUU. Err_PUU Before command Fb_PUU issued Cmd_O Cmd_E After command Err_PUU Fb_PUU issued Cmd_O Cmd_E Err_PUU Command in Fb_PUU execution Cmd_O Cmd_E Err_PUU Command completed Fb_PUU Cmd_O Cmd_E Err_PUU Motor positioned Fb_PUU Cmd_O Cmd_E Figure 7.1.2.1 Timing diagram for PR mode monitoring variables 7-6