Delta Electronics — 7.1.3.1 Homing methods

ASDA-B3 Motion Control 7 Figure 7.1.3.1.2 Homing screen in ASDA-Soft The following describes the homing methods supported by the ASDA-B3. They can be categorized into six types based on their reference points. 1. Referencing the limit. This method uses the positive or negative limit as the reference point. When the limit is detected, you can choose whether or not to look for the Z pulse and use it as the reference origin. The searching result is the same regardless of where the start point is. The ASDA-B3 always looks for the set reference point to reset the coordinates.

Limit Motor (a) Reverse to Z End Start point Start point 1 (b) Go forward to Z Start point 2 End (c) Do not look for Z Start point Z pulse Limit signal 7-13 End