Delta Electronics — 7.1.3.1 Homing methods

Motion Control ASDA-B3 7 Settings: The first speed setting for high speed homing. First high speed homing First high speed homing ORG Second low speed homing Z Pulse Z Pulse Settings: The second speed setting for low speed homing. You can set the homing parameters in the PR mode homing screen in ASDA-Soft, including the Homing Mode, Homing Speed Setting, and Homing Definition (see Figure 7.1.3.1.2). 7-12 Address: 050AH P5.005 High speed homing (first speed setting) 050BH Operation Panel / software Communication Control mode: interface: Default: 100.0 1000 Data size: Unit: 1 rpm 0.1 rpm - Setting range: 0.1 - 2000.0 1 - 20000 - Format: DEC DEC - Example:

1.5 = 1.5 rpm 15 = 1.5 rpm - Second low s ORG ming Address: 050CH P5.006 Low speed homing (second speed setting) 050DH Operation Panel / software Communication PR (set with P5.004) Control mode: interface: Default: 20.0 200 Data size: 32-bit Unit: 1 rpm 0.1 rpm - - Setting range: 0.1 - 500.0 1 - 5000 - - Format: DEC DEC - - Example: 1.5 = 1.5 rpm 15 = 1.5 rpm - -