Delta Electronics — 7.1.3.1 Homing methods

ASDA-B3 Motion Control The PR Homing mode includes the function for setting the origin offset. You can define any point on the coordinate axis as the reference origin, which does not have to be 0. Once you define the reference origin, the system can create the coordinate system for the motion axis. See Figure 7.1.3.1.1. The coordinate for the reference origin is 2000 (P6.001 = 2000). The motor 7 passes by the reference origin and then stops at coordinate 1477. From the coordinate system that it created, the system automatically calculates the position of 0 point. As soon as the PR motion command is issued, the motor moves to the specified position. P6.001:

Origin definition 2000 Coordinates (after homing) 1000 3000 - 1000 5000 0 4000 Origin 1477 Motor position (after homing) H L Reverse to Z E S1 Z pulse Reference PL signal origin Figure 7.1.3.1.1 Origin definition Settings: Origin definition. The homing procedure goes through two stages: high speed and low speed. The servo starts the homing procedure at high speed to seek the reference point (such as the limit switch and ORG signal), which takes shorter time. Once the servo detects the reference point, the motor runs at low speed to find the reference point accurately (such as the Z pulse). The speeds for the two stages are defined by P5.005 and P5.006. 7-11 Address:

0602H P6.001 Origin definition 0603H Default: 0 Control mode: PR Unit: - Setting range: -2147483648 to +2147483647 Format: DEC Data size: 32-bit