Motion Control ASDA-B3 7 Settings: Homing definition: High bit Low bit B C D A YX Z U YX: PATH: Path type 0x00: Stop: homing complete and stop 0x01 - 0x63: Auto: homing complete and execute the specified path (Path#1 - Path#99) Z: ACC: select 0 - F for acceleration time 0 - F: correspond to P5.020 - P5.035 U: DEC1: deceleration time selection for first homing 0 - F: correspond to P5.020 - P5.035 A: DEC2: deceleration time selection for second homing 0 - F: correspond to P5.020 - P5.035 B: DLY: select 0 - F for delay time 0 - F: correspond to P5.040 - P5.055 D: BOOT: when the drive is powered on, whether to search for origin. 0: do not execute homing 1:
execute homing automatically (servo switches to on for the first time after applying power) 7-10 U Z Y X - - X = 8: define current position as the origin When reaching the limit: Z = 0: show error Z = 1: reverse direction Y = 0: return to Z pulse Y = 2: do not look for Z pulse X = 9: torque homing in forward direction X = A: torque homing in reverse direction Address: 0600H P6.000 Homing definition 0601H Default: 0x00000000 Control mode: PR Unit: - Setting range: 0x00000000 - 0xFFFFFF6F Format: HEX Data size: 32-bit A DEC2: deceleration time selection for second homing YX PATH: path type B DLY: select 0 - F for delay time Z ACC: select 0 - F for acceleration time C N/A U DEC1:
deceleration time selection for first homing D BOOT - -