Delta Electronics — 7.1.3.2 Speed command

ASDA-B3 Motion Control Speed Target speed Delay time 7 Feedback speed Acceleration time Command Time Speed Feedback speed Command Delay time Target speed Deceleration time Time Figure 7.1.3.2.2 Parameters for PR mode speed control Table 7.1.3.2.1 Bit functions of PR speed control Note: 1. Y: OPT: option INS: Interrupt command that interrupts the previous motion command. AUTO: automatically load the next PR command when the current one is complete. UNIT: speed unit selection; 0 signifies 0.1 rpm and 1 signifies PPS. 2. Z, U: ACC / DEC: acceleration / deceleration time, set by P5.020 - P5.035. 3. B: DLY: delay time, set by P5.040 - P5.055.

7-23 D C B A U Z Y X PR parameters Command type - - DLY - DEC ACC OPT 1 Data content Target speed [0.1 rpm / PPS] BIT 3 2 1 0 Command type - UNIT AUTO INS