Motion Control ASDA-B3 7.1.3.2 Speed command The PR mode includes a speed control function. The following parameters are available for PR speed setting: acceleration / deceleration time, delay time, and target speed. You can easily set 7 the Speed command in the PR mode screen in ASDA-Soft. See Figure 7.1.3.2.1.  INS is an interrupt command that interrupts the previous motion command. Refer to Section 7.1.6 for more details.  AUTO is a command that automatically loads and executes the next PR path when the current PR path completes. You can set the target speed with two unit options, 0.1 rpm and 1 PPS, and the setting range is -6000 rpm to 6000 rpm.

 ACC / DEC is the acceleration / deceleration time determined by the shared PR parameters. The software calculates and displays the required duration for accelerating from 0 to the target speed.  DLY is the delay time that is determined by the shared PR parameters. It delays the command; in other words, the delay time is the time to wait after the target speed command completes. See Figure 7.1.3.2.2 for the effects of the parameters for the PR mode speed control. Table 7.1.3.2.1 shows the bit functions when speed control is in operation. Figure 7.1.3.2.1 PR mode Speed control screen in ASDA-Soft 7-22