ASDA-B3 Motion Control As mentioned in Section 7.1.2, the PR mode provides four monitoring variables for you to monitor the servo commands and feedback status. These are Command position PUU (Cmd_O), PR command end register (Cmd_E), Feedback position PUU (Fb_PUU), and Position error PUU (Err_PUU). Before homing completes, the command end register (Cmd_E) cannot be 7 calculated because the coordinate system can only be created after homing is complete, and the target position remains unknown after the Homing command is issued. This is why the status of each monitoring variables is different during homing. In Homing command’s default setting, the contents of Cmd_E and Cmd_O are identical.
After the servo finds the reference origin and creates the coordinate system, it sets the content of Cmd_E to the coordinate of the reference origin. However, once the servo finds the reference origin, it still requires some distance for motor to decelerate to a stop. Meanwhile, Cmd_O continues to issue commands. If no other PR commands are issued after homing (other than the Position command), the contents of the final command position (Cmd_O) and command end position (Cmd_E) will be different. See Figure 7.1.3.1.3.
Err_PUU Before command Fb_PUU issued Cmd_O Cmd_E After command Err_PUU Fb_PUU issued Cmd_O Cmd_E Err_PUU Command in execution Fb_PUU Cmd_O Cmd_E Err_PUU Command completed Fb_PUU Cmd_O Cmd_E Err_PUU Motor positioned Fb_PUU Cmd_O Cmd_E Figure 7.1.3.1.3 Homing mode and monitoring variables 7-21