Delta Electronics — 7.1.3.4 Jump command

Motion Control ASDA-B3 7.1.3.4 Jump command The PR mode includes a Jump command. It can call any PR paths or form PR paths into a loop, as shown in Figure 7.1.3.4.1. You can specify the PR path number to jump to in the PR mode 7 screen in ASDA-Soft (see Figure 7.1.3.4.2).  INS is an interrupt command that interrupts the previous motion command. Refer to Section 7.1.6 for more details.  DLY is the delay time that is determined by the shared PR parameters. Once a Jump command is issued, the servo drive starts counting the delay time.  Available target PR numbers are PR#00 - PR#99. Table 7.1.3.4.1 shows the bit functions when a Jump command is in operation.

PR #01 Jump Jump PR #07 PR #08 PR #09 PR #10 Figure 7.1.3.4.1 Jump command in PR mode Figure 7.1.3.4.2 PR Mode Jump command screen in ASDA-Soft 7-28