Delta Electronics — 7.1.3.6 Index Position command

ASDA-B3 Motion Control Table 7.1.3.6.1 Bit functions of the PR Index Position command 7 Note: 1. Y: OPT: option INS: Interrupt command that interrupts the previous motion command. OVLP: allow overlapping of the next command. 2. C: OPT2: option 2 S_LOW: speed unit options, 0 stands for 0.1 r/min and 1 for 0.01 r/min. AUTO: automatically load the next PR command when the current one is complete. 3. Z, U: ACC / DEC: acceleration / deceleration time, set by P5.020 - P5.035. 4. A: SPD: target speed, set by P5.060 - P5.075. 5. B: DLY: delay time, set by P5.040 - P5.055.

7-35 BIT D C B A U Z Y X PR parameters Command type - OPT2 DLY SPD DEC ACC OPT Data content BIT 3 2 1 0 Description Command type DIR OVLP INS 0 0 - - 0 1 Data content 1 0 1 1 BIT 3 2 1 0 Command type - AUTO -