Delta Electronics — 7.1.4 Overview of the PR procedure

Motion Control ASDA-B3 7.1.4 Overview of the PR procedure In the PR mode, there are six types of commands. To make users understand how the PR procedure works, ASDA-Soft presents the execution order and calling sequence of all PR 7 procedures. The symbols and contents in the PR diagram are shown as follows. This includes five parts: number, command execution type (property), command type, next procedure command, and command information. See Figure 7.1.4.1. (1) PR#1 (I)(O) (2) Position (3) DLY = [0] 0 ms 100000 PUU (4) INC 200 rpm (5) Figure 7.1.4.1 Overview of the PR procedure (1) Number: the PR number, ranging from PR#0 to PR#99 (100 sets of PR paths). (2) Command execution type (property):

(B) execute homing when power on; (O) command overlap; (R) write data to EEPROM; (I) command interrupt. (3) Command type: there are five types of PR procedure commands: homing, speed, position, writing, and jumping. The color displayed in this section depends on the command type. (4) Next procedure command: if followed by a PR command, there would be an arrow pointing to the specified PR path. (5) Command information: displays the details of this PR path. The displayed contents and color depend on the information type. The following sections illustrate each command type and its representation. 7-36