Delta Electronics — 7.1.4 Overview of the PR procedure

Motion Control ASDA-B3 Speed command You can use the Speed command in any PR paths (PR#1 - PR#99). It is marked as “Speed”. See Figure 7.1.4.3. 7 PR#1 (I) (1) Speed 100 rpm Acc = [0] 6.67 ms Dec = [0] 6.67 ms DLY = [0] 0 ms (2) (3) (4) (5) Figure 7.1.4.3 Speed command display (1) Command execution type (property): a Speed command can interrupt (INS) the previous PR path. If the Interrupt function is enabled, it displays (I); if not, no information is displayed. (2) Delay time (DLY): determined by the shared PR parameters. It is defined by a command from the controller; the servo drive starts counting the delay time once it reaches the target speed. (3) Target speed: the set target speed.