ASDA-B3 Motion Control Position command You can use the Position command in any PR paths (PR#1 - PR#99). It is marked as “Position”, and includes the options to “Stop once position control completed” and “Load the next path once position control completed”. The only difference is that “Load the next path once position 7 control completed” shows an arrow pointing to the next PR. See Figure 7.1.4.4. (1) (2) (3) (4) (5) (6) (7) Figure 7.1.4.4 Position command display (1) Command execution type (property): a Position command can interrupt (INS) the previous PR path. If the Interrupt function is enabled, it displays (I); if not, no information is displayed.
The Position command can overlap (OVLP) the next PR path. Set the delay time to 0 when using this function. If the Overlap function is enabled, it displays (O); if not, no information is displayed. (2) Delay time (DLY): determined by the shared PR parameters. It is defined by a command from the controller. The servo starts counting the delay time once reaching the target position. (3) Target position: the set target position. (4) Position command type: “ABS” means absolute positioning; “REL” means relative positioning; “INC” means incremental positioning; “CAP” means high-speed position capturing. (5) Target speed: determined by the shared PR parameters. (6) Acceleration time (ACC):
determined by the shared PR parameters; length of time to reach the target speed from stopped. (7) Deceleration time (DEC): determined by the shared PR parameters; length of time to decelerate from target speed to stopped. 7-39 PR#1 (I)(O) Position DLY = [0] 0 ms 100000 PUU ABS 200 rpm Acc=[0] 6.67 ms Dec=[0] 6.67 ms PR#1 (I)(O) Position DLY = [0] 0 ms 100000 PUU ABS 200 rpm Acc=[0] 6.67 ms Dec=[0] 6.67 ms