ASDA-B3 Motion Control Select the PR number to be executed based on the on / off status of DI.POS0 - 6 and use DI.CTRG to trigger the specified PR path. See Figure 7.1.5.1 for an example. Table 7.1.5.1 Use DI to select the PR path to be triggered 7 In addition, there are two sets of DI for special functions: [0x27] Enable homing and [0x46] Motor stops. If the former is triggered, the servo drive executes homing based on the homing setting. If the latter is triggered, the servo drive stops the motor. You can use the DI/O setting screen in ASDA-Soft to set these functions, as shown in Figure 7.1.5.2.
Figure 7.1.5.2 DI/O setting screen in ASDA-Soft 7-43 Position command POS 6 POS 5 POS 4 POS 3 POS 2 POS 1 POS 0 CTRG Correspon- ding parameter Homing 0 0 0 0 0 0 0 P6.000 P6.001 PR#1 0 0 0 0 0 0 1 P6.002 P6.003 … … PR#50 0 1 1 0 0 1 0 P6.098 P6.099 PR#51 0 1 1 0 0 1 1 P7.000 P7.001 … … PR#99 1 1 0 0 0 1 1 P7.098 P7.099