Delta Electronics — 7.1.5 Trigger methods for the PR command

Motion Control ASDA-B3 Event triggering For the event triggering method, you use Event trigger commands 1 - 4 to execute the specified PR path. There are two types of Event triggering: rising-edge trigger and falling-edge trigger. 7 The range of PR path numbers that you can specify is from 51 - 63 (see the example in Figure 7.1.5.3). Before using the event triggering for PR commands, you must define the DI functions, which are [0x39] Event trigger command 1, [0x3A] Event trigger command 2, [0x3B] Event trigger command 3, and [0x3C] Event trigger command 4 (see Table 8.1). You can use the DI/O setting screen in ASDA-Soft to set these functions, as shown in Figure 7.1.5.4. DI 2: [0x39] DI 3:

[0x3A] PR path No. to be executed Figure 7.1.5.3 Example of event triggering timing diagram Figure 7.1.5.4 DI/O setting screen in ASDA-Soft 7-44 mmand 1 #51 PR PR ommand 2 #52 #62 62 PR 52 PR 51 #63 63