Delta Electronics — 7.1.6 PR procedure execution flow

Motion Control ASDA-B3  Position command followed by a Position command When the PR executor receives two consecutive Position commands, if they do not have Interrupt or Overlap functions, the PR executor issues the first Position command to the motion command 7 generator, and the generator starts the first part of position control. After the first Position command completes, if no delay time is set, the PR executor issues the second Position command for the generator to start the second part of position control (see Figure 7.1.6.2 (a)). If the first Position command includes a delay, the PR executor starts counting the delay time right after the motor reaches the target position.

Then it issues the second Position command for the generator to start the second part of position control as shown in Figure 7.1.6.2 (b). (1 ms command cycle) (1 ms command cycle) PR executor Motion command generator Time (a) Position command without delay (1 ms command cycle) (1 ms command cycle) PR executor Motion command generator Time 100 ms (b) Position command with delay Figure 7.1.6.2 Position sequence command 7-48 PR#1 PR#2 Position Position DLY=[0] 0 ms DLY=[0] 0 ms 10000 PUU 10000 PUU ABS ABS 200 rpm 500 rpm peed PR#1 PR#2 Position Position DLY=[1] 100 ms DLY=[0] 0 ms 10000 PUU 10000 PUU ABS ABS 200 rpm 500 rpm eed