Delta Electronics — 7.1.6 PR procedure execution flow

ASDA-B3 Motion Control  Speed command followed by a Speed command When the PR executor receives two consecutive Speed commands, if they do not have Interrupt or Overlap functions, the PR executor issues the first Speed command to the motion command generator, and the generator starts the first part of speed control. After the first Speed 7 command completes, if no delay time is set, the PR executor issues the second Speed command for the generator to start the second part of speed control (see Figure 7.1.6.3 (a)). If the first Speed command includes a delay, the PR executor starts counting the delay time right after the motor reaches the target speed.

Then it issues the second Speed command for the generator to start the second part of speed control as shown in Figure 7.1.6.3 (b).

(1 ms command cycle) (1 ms command cycle) PR#1 PR#2 PR executor Speed Speed 100 rpm Acc=[11] 100 ms Dec=[11] 100 ms DLY=[0] 0 ms 500 rpm Acc=[0] 33.3 ms Dec=[0] 33.3 ms DLY=[0] 0 ms Motion command generator Time (a) Speed command without delay (1 ms command cycle) (1 ms command cycle) PR#1 PR#2 PR executor Speed Speed DLY=[1] 100 ms DLY=[0] 0 ms 100 rpm Acc=[11] 100 ms Dec=[11] 100 ms 500 rpm Acc=[0] 33.3 ms Dec=[0] 33.3 ms Speed (rpm) Motion command 500 generator 100 Time (b) Speed command with delay 100 ms Figure 7.1.6.3 Speed sequence command 7-49 d (rpm) 00 00