Delta Electronics — 7.1.6 PR procedure execution flow

Motion Control ASDA-B3  Multiple commands The PR queue updates commands every 1 ms. For a motion command, the PR queue sends the next command to the generator only after the previous command completes. Jump or Write 7 commands are executed in the PR queue immediately. As shown in Figure 7.1.6.4, in the first ms, the PR queue receives a Position command and sends this command to the motion command generator, having the generator to execute the command. In the second ms, the PR queue receives a Write command and executes it immediately. In the third ms, the PR queue receives a Jump command and executes it immediately as well.

These last two commands are not sent to the motion command generator since the PR queue and the generator can execute commands independently. In the fourth ms, the PR queue receives a Position command. Next, the PR executor sends this Position command to the generator for execution. (1 ms Cmd cycle) (1 ms Cmd cycle) PR executor Motion command generator Time Figure 7.1.6.4 Multiple sequence commands 7-50 (1 ms Cmd cycle) (1 ms Cmd cycle) PR#1 PR#5 PR#2 PR#3 Position Position Write Jump DLY=[0] 0 ms DLY=[0] 0 ms 5000 PUU DLY=[0] 0 ms DLY=[0] 0 ms 10000 PUU ABS P5.045=100 PR#5 ABS 200 rpm 500 rpm PR#5 Position DLY=[0] 0 ms 10000 PUU ABS 500 rpm eed T