Delta Electronics — 7.1.6 PR procedure execution flow

Motion Control ASDA-B3 ( 1 ms Cmd cycle ) (1 ms Cmd cycle) PR executor 7 Motion command generator Time (a) Position command without delay (1 ms Cmd cycle) (1 ms Cmd cycle) (1 ms Cmd cycle) PR executor Motion command generator Time 500 ms (b) Position command with delay Figure 7.1.6.6 Internal interruption - Position command Note: the integration for internal interrupt position command is slightly different from what is described in Section 7.1.3. The way REL and INC commands work is identical. The target position is the previous target position plus the current position. See the following example. The rest of the integration method is the same as mentioned in Section 7.1.3.

Motor s current position (Fb_PUU) Endpoint of previous command (Cmd_E) 60000 Target position Internal interruption REL (I) 60000 PUU 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 Motor s current Endpoint of previous command (Cmd_E) 60000 Internal interruption position (Fb_PUU) Target position INC (I) 60000 PUU 0 10000 20000 30000 40000 50000 60000 70000 80000 90000 100000 Figure 7.1.6.7 Example of relative and incremental position commands for internal interruption 7-52 PR#1 PR#2 (I) PR#3 Position Position Position DLY=[0] 0 ms DLY=[0] 0 ms DLY=[0] 0 ms 1000 PUU 5000 PUU 10000 PUU ABS ABS ABS 100 rpm 200 rpm 500 rpm peed T PR#1 PR#2 (I) PR#3 Position Position Position DLY=[4] 500 ms DLY=[0] 0 ms DLY=[0] 0 ms 10000 PUU 50000 PUU 100000 PUU ABS ABS ABS 100 rpm 200 rpm 500 rpm eed