ASDA-B3 Motion Control 2. External Interruption If an external interruption is encountered, it uses the PR Command trigger method to execute another PR path (refer to Section 7.1.5 for PR trigger methods). When the PR queue receives a PR path with an Interrupt function, it sends this path to the motion command generator 7 immediately and changes the path in execution. Note that a delay does not change the result of an external interruption. That is, once the PR queue receives an external interrupt command, the motion commands in the latter part are executed by the generator and integrated with the previous commands. The external interruption is as shown in Figure 7.1.6.10 (a).
If a PR path with an Interrupt function enters the PR executor as an external interruption, the executor sends this Position command immediately to the generator so that the motor can run in accordance with the interruption. The motor uses the settings that integrate with the former motion commands when running. The methods of integration are described in Section 7.1.3. Similarly, an external interruption affects Speed and Position commands the same way and the same is true for multiple commands. See Figure 7.1.6.10 (b) for an example.
(1 ms command cycle) (1 ms command cycle) External PR executor Motion command generator (a) External interruption - Position command 7-55 PR#1 interruption PR#2 Position Position DLY=[0] 0 ms DLY=[0] 0 ms 1000 PUU 10000 PUU ABS ABS 100 rpm 200 rpm (1 ms command cycle) (1 ms command cycle) PR#10 (I) PR#11 Position Position DLY=[0] 0 ms DLY=[0] 0 ms 5000 PUU 10000 PUU ABS ABS 200 rpm 500 rpm eed T