Motion Control ASDA-B3 7.2.2 High-speed position capture function (Capture) The high-speed position capturing function (CAP) uses the external-triggered high-speed digital input DI3 (B3-F, M) or DI7 (B3-L) (with execution time of only 5 µs) to capture the position data 7 of the motion axis and store it in the data array for further motion control. As the Capture function is executed by the hardware, there is no lag in the software, and it is able to capture the motion axis’ position accurately. While the Capture function is enabled, the servo drive sends a DI signal for the capture signal (the DI is not user-defined).
The flowchart for high-speed position capturing is shown in Figure 7.2.2.1. The relevant parameters are defined as follows. P5.036 sets the start position in the data array for storing the captured data; if it is not set, the default start position is #0. P5.038 sets the capturing amount. The amount has to be greater than 0, otherwise the Capture function is not executed. P1.019.X enables the cycle mode. When the last data is captured, the capturing amount is reset to 0 (P5.038 = 0), and the next cycle starts automatically to capture the set capturing amount.
However, the start position for storing the captured position data is still determined by P5.036; that is, the captured data in the previous cycle is replaced by the data captured in the next cycle. P5.039 enables and disables the Capture function and other settings. See the following table for more information. To capture multiple position data, use P1.020 to set the masking range for capturing. This prevents the same position data being captured repeatedly because capturing more than once is not allowed in the masked area. You can set the Capture function in ASDA-Soft, as shown in Figure 7.2.2.2.
7-62 P5.039 Bit Function Description X 0 Enable Capture function When P5.038 > 0 and bit 0 = 1, the capturing starts and DO.CAP OK is off. Each time a position is _ captured, the value of P5.038 is decremented by 1. When P5.038 = 0, it means the capturing is finished, DO.CAP OK is on, and bit 0 is reset to 0. If bit 0 is _ already 1, the written value must not be 1; you must write 0 to disable the Capture function. 1 Reset position when first data is captured If bit 1 = 1, after the first data is captured, set the Capture axis’ position to the value of P5.076. 2 Reserved - 3 Execute PR#50 after the last data is captured If bit 3 = 1, execute PR#50 once all data are captured.
Y - Source of Capture axis 0: disabled 1: reserved 2: CN1 3: CN2 Z - Trigger logic 0: NO (normally open) 1: NC (normally closed) U - Minimum trigger interval (ms) -