ASDA-B3 Motion Control CAP axis source CAP triggering logic Normally open P5.039.Z = 0 DI4 P5.037 CAP switch P5.039.X Bit 0 CAP axis position CN1 P5.039.Y = 2 CN2 P5.039.Y = 3 7890 7 DI4 Normally closed P5.039.Z = 1 Data array Reset the 1 st position P5.036 CAP amount Start address P5.039.X Bit 1 = 1 1 st position = P5.076 P5.038 Enable CMP after the 1 st data is captured P5.039.X Bit 2 = 1 CAP amount P5.038 = P5.038 - 1 CAP completed? P5.038==0 No Yes Call PR#50 P5.039.X Bit 3 = 1 Cyclic CAP P1.019.X = 1 P5.038 = default value Figure 7.2.2.1 Flowchart for high-speed position capturing Figure 7.2.2.2 Capture function screen in ASDA-Soft 7-63 1234 2345 5678 6789 7890