Delta Electronics — 8.2 List of parameters

Parameters ASDA-B3 Gain and switching parameters 8 ( ★ ) Read-only parameter. Can only read the value of the parameter. For example, P0.000, P0.010, and P4.000. (▲) Parameter cannot be changed when servo is in Servo On status. For example, P1.000 and P1.046. ( ● ) Parameter changes become valid after power cycling. For example, P1.001 and P3.000. ( ■ ) Parameter resets to its default value after power cycling. For example, P3.006. 8-6 Parameter Control mode Function Default value Unit No.

PT PR S T P1.037 Load inertia ratio 6.0 0.0 (B3-F) (panel / software) 1 times (panel / software) O O O O 60 0 (B3-F) (communication) 0.1 times (communication) P2.000 Position control gain 35 rad/s O O - - P2.001 Position control gain rate of change 100 % O O - - P2.002 Position feed forward gain 50 % O O - - P2.003 Position feed forward gain smoothing constant 5 ms O O - - P2.004 Speed control gain 500 rad/s O O O O P2.005 Speed control gain rate of change 100 % O O O O P2.006 Speed integral compensation 100 rad/s O O O O P2.007 Speed feed forward gain 0 % O O O O P2.026 Anti-interference gain 0 rad/s O O O O P2.027 Gain switching condition and method selection 0x0000 - O O O O P2.028 Gain switching time constant 10 ms O O O O P2.029 Gain switching condition 16777216 pulse kpps rpm O O O O P2.031 Bandwidth response level 19 - O O O O P2.032 Gain adjustment mode 0x0001 0X0000 (B3-F) - O O O O P2.053 Position integral compensation 0 rad/s O O O O P2.089 Command response gain 25 rad/s O O - - P2.094▲ Special bit register 3 0x1010 0X0010 (B3-F) - O O O - P2.104 P/PI torque switching command condition 800 % O O O - P2.105 Automatic gain adjustment level 1 11 - O O - - P2.106 Automatic gain adjustment level 2 2000 pulse O O - - P2.112▲ Special bit register 4 0x0018 - O O O -