ASDA-B3 Parameters Position control parameters 8 Position control parameters - external pulse control command (PT mode) 8-7 Parameter Control mode Function Default value Unit No.
PT PR S T Input for control mode and control command 0x0000 0x000B (B3-F) - O O O Speed and torque limits 0x0000 - O O O Encoder pulse output polarity 0x0000 - O O O Internal Torque command / internal torque limit 1 - 3 100 % O O O E-Gear ratio (numerator) (N1) 16777216 pulse O O - E-Gear ratio (denominator) (M) 100000 pulse O O - Encoder pulse number output 2500 pulse O O O Maximum speed limit Rated speed rpm O O O Encoder output denominator (OA, OB) 0 - O O O Deceleration time for auto-protection 0xEEEFEEFF - - O O Acceleration / deceleration times (Number #0 - 15) Refer to description of each parameter ms - O - Axis position - motor encoder 0 PUU O O O Axis position - pulse command 0 pulse O O O Parameter Function Control mode Default value Unit No.
PT PR S T P1.000▲ External pulse input type 0x1042 - O - - - P2.060 E-Gear ratio (numerator) (N2) 16777216 pulse O - - - P2.061 E-Gear ratio (numerator) (N3) 16777216 pulse O - - - P2.062 E-Gear ratio (numerator) (N4) 16777216 pulse O - - -