Delta Electronics — 8.2 List of parameters

Parameters ASDA-B3 Position control parameters - internal register control command (PR mode) 8 ( ★ ) Read-only parameter. Can only read the value of the parameter. For example, P0.000, P0.010, and P4.000. (▲) Parameter cannot be changed when servo is in Servo On status. For example, P1.000 and P1.046. ( ● ) Parameter changes become valid after power cycling. For example, P1.001 and P3.000. ( ■ ) Parameter resets to its default value after power cycling. For example, P3.006. 8-8 Parameter Control mode Function Default value Unit No.

PT PR S T P5.008 Positive software limit 2147483647 PUU - O - - P5.009 Negative software limit -2147483648 PUU - O - - P6.002 - P7.099 Internal Position commands (Path definition) #1 - 99 0 - - O - - P5.060 - P5.075 Speed control for internal Position commands (target speed setting) #0 - 15 20.0 - 3000.0 (panel / software) 1 rpm (panel / software) - O - - 200 - 30000 (communication) 0.1 rpm (communication) P5.004 Homing methods 0x0000 - - O - - P5.005 High speed homing (first speed setting) 100.0 (panel / software) 1 rpm (panel / software) - O - - 1000 (communication) 0.1 rpm (communication) - O - - P5.006 Low speed homing (second speed setting) 20.0 (panel / software) 1 rpm (panel / software) - O - - 200 (communication) 0.1 rpm (communication) - O - - P5.007■ Trigger Position command (PR mode only) 0 - - O - - P5.040 - P5.055 Delay time after position reached (Number #0 - 15) 0 - 5500 ms - O - - P5.098 PR# triggered by event rising-edge 0x0000 - - O - - P5.099 PR# triggered by event falling-edge 0x0000 - - O - - P5.015■ PATH#1 - PATH#2 volatile setting 0x0000 - - O - -