Delta Electronics — P0.xxx Monitoring parameters

Parameters ASDA-B3 Write: in the mapping content, set P0.025 to 0x00050064, and the values of P2.003 and 8 P2.005 are: P0.025 P2.003 0005 P2.005 0064 2. When PH = PL = P, it indicates that the content of P0.025 includes one 32-bit parameter. Example: Target: set P6.010 to 0x00050064 in the mapping parameter. Setting: set both the high bit and low bit of P0.035 to 060A (P6.010). Thus, P6.010 = 0x060A060A. P0.035 Write: in the mapping content, set P0.025 to 0x00050064 and P6.010 changes immediately. Settings: High bit Low bit P0.036 P0.026 Settings: High bit Low bit P0.037 P0.027 8-20 0005 0064 P6.010 P6.010 Address: 0048H P0.036 Target setting for mapping parameter P0.026 0049H Default:

- Control mode: All - Determined by the communication address of the parameter group Unit: Setting range: Format: HEX Data size: 32-bit Position of mapping parameter Position of mapping parameter Content of mapping parameter Content of mapping parameter Address: 004AH P0.037 Target setting for mapping parameter P0.027 004BH Default: - Control mode: All - Determined by the communication address of the parameter group Unit: Setting range: Format: HEX Data size: 32-bit Position of mapping parameter Position of mapping parameter Content of mapping parameter Content of mapping parameter